Heat shrinkable tubing 2:1 - flexible and coloured
Art.-No. 305-09542
| HFT-A 95-PO-X-CL
|
Copied
- Flexible heat shrink tubing
- Fast shrinking, easy handling, good mechanical strength
- Wide range of colours
- Internal diameters up to 102 mm (4 inches)
- UL-224 ,CSA listed and VG approved
Show more
줄이기
More products in this product group:
| Application | This high performance thin wall tubing is used extensively for electrical and mechanical protection. It is also well proven for sleeve marking to identify wiring circuits. |
| Behaviour At Low Temperature | not cracking |
| Behaviour at low Temperature test method | IEC 60684-2 |
| Colour | Transparent (CL) |
| Description | The HTF-A series heat shrink tubing features a thin wall, flexible polyolefin construction and a 2:1 shrink ratio, allowing it to conform easily to a wide range of component shapes and diameters. This tubing is UL-224 and CSA approved, making it well-suited for high-heat and demanding electrical applications. The durable polyolefin material provides excellent electrical insulation, strong mechanical protection and reliable resistance to chemicals and solvents. |
| Heat Shock Elongation | 390% |
| Heat Shock Tensile Strength | 13MPa |
| Heat Shock Test | 4h/200°C |
| Heat shock test test method | IEC 60684-2 |
| Material | Polyolefin, cross-linked (PO-X) |
| PART DESCRIPTION | HFT-A 95-PO-X-CL |
| Pack Content | 50m |
| Package Content packed in | lengths |
| Printable | No |
| Product Family | HFT-A - self extinguishing |
| Product Group | Heat shrinkable tubing 2:1 - flexible and coloured |
| Shrink Ratio | 2:1 |
| Size | 3/8" |
| Type | HFT-A 95 |
| Variant | Thin-Wall |
| With inner glue (Yes/No) | No |
| Dielectric Strength | 21kV/mm |
| Dielectric Strength test method | IEC 60684-2 |
| Elongation at break (min.) | 400% |
| Elongation at break test method | IEC 60684-2 |
| Halogen-free | No |
| Insulation Class | B (VDE 0530) |
| Min. Shrink Temperature - °C | +135 °C |
| Operating Temperature | -55 °C to +135 °C |
| ROHS compliant | Yes |
| Specifications |
|
| Specifications | UL 224 125 °C 600V |
| Tensile Strength | 14MPa |
| Test Method Tensile Strength | IEC 60684-2 |
| UL File link | Link |
| UL-File Number | E143529 |
| Volume Resistance | 10¹⁴ Ω cm |
| Volume Resistance test method | IEC 60684-2 |