Integrated Routing Multi-Business Unit
						Art.-No. 857-01070
						| ENIR-MBU-12SE
						| 
						
					Copied
					- Maximum 288 fibre splice capacity
- Accommodates SC-IR or SE-IR Trays
- Loop storage/loop through provision
- Lockable removable cover
- Positive fibre management to ensure consistent 30mm bend radii throughout
- Maximum 30 cable entry/exit points
- Optional connectorisation on user side when used with the ENIR-MBU-CB
 
											
										More products in this product group: 
									
| Content | Main Enclosure IR MBU Closure 12 SE trays Cable Management Kit Wall Mounting Kit 2 x Blanking Panels | 
| PART DESCRIPTION | ENIR-MBU-12SE | 
| Product Family | Fibre Optic Internal Enclosure | 
| Product Group | Integrated Routing Multi-Business Unit | 
| Technical Description | The Integrated Multi-Business Unit can be used in isolation or as a connectorised solution when used with the ENIR-MBU-CB Customer Access Box.  The enclosure is manufactured from powder coated mild steel and has 30 knock-out cable gland positions which provide a high level of flexibility when managing cable routing and mid-span/loop through applications. The enclosure accommodates a maximum of 12 SE or 24 SC-B trays which are mounted on an IR fibre management module which can be detached from the compartment for ease of access and to facilitate fibre routing. The modular design of the trays and the fibre optic routing module allow for the trays to be easily clipped in to place. The system allows for easy routing of fibre on to the trays. The trays and the fibre optic routing module are white which makes it easy to see the colour of the fibre elements as they are routed through the positive fibre management system. Fibre slot retaining blocks guide fibre elements in to the IR system, the foam pad on the retainer is partially cut through to accommodate a range of fibre counts, and the plug is keyed so that it can only be inserted in one direction. The fibre can be connected to an adaptor or spliced to a fibre pigtail and connected to the Customer Access Box providing a connectorised solution, or alternatively the brush strip management kit can be used to route the fibre directly from the enclosure to the end user. The enclosure is fitted with a secure locking cover ad comes supplied with a blanking panel which can be removed when used with the Customer Access Box. | 
| Type | ENIR-MBU-12SE | 
 Argentina
Argentina Australia
Australia Brazil
Brazil Bulgaria
Bulgaria China
China Czech Republic
Czech Republic Denmark
Denmark Finland
Finland France
France Germany
Germany Hungary
Hungary India
India Italy
Italy Netherlands
Netherlands North America
North America Norway
Norway Poland
Poland Portugal
Portugal Romania
Romania Russia
Russia Singapore
Singapore Slovenia
Slovenia South Africa
South Africa South Korea
South Korea Spain
Spain Sweden
Sweden Switzerland
Switzerland Türkiye
Türkiye United Arab Emirates
United Arab Emirates United Kingdom
United Kingdom 
	 
										 
															 
															 
															 
															 
															 
															 
															 
															
 Download
						Download
					
 ENIR-BRUSHKIT
							857-40383
						
							ENIR-BRUSHKIT
							857-40383 ENIR-GK
							857-40376
						
							ENIR-GK
							857-40376 ENIR-SGP
							857-40377
						
							ENIR-SGP
							857-40377 ENIR-CP-LCDX/APC
							857-40395
						
							ENIR-CP-LCDX/APC
							857-40395 ENIR-CP-LCDX/PC
							857-40396
						
							ENIR-CP-LCDX/PC
							857-40396 ENIR-CP-LCSX/APC
							857-40397
						
							ENIR-CP-LCSX/APC
							857-40397 ENIR-CP-SCDX/APC
							857-40399
						
							ENIR-CP-SCDX/APC
							857-40399 FFO-LC-SMA2-30M-FX1/R
								855-35026
							
								FFO-LC-SMA2-30M-FX1/R
								855-35026 FFO-LP-SMA2-30M-FX1/R
								855-35027
							
								FFO-LP-SMA2-30M-FX1/R
								855-35027 FFO-SC-SMA2-30M-FX1/R
								855-35028
							
								FFO-SC-SMA2-30M-FX1/R
								855-35028 FFO-SP-SMA2-30M-FX1/R
								855-35029
							
								FFO-SP-SMA2-30M-FX1/R
								855-35029 BFP1019C
								857-00009
							
								BFP1019C
								857-00009 CPU3862
								857-00349
							
								CPU3862
								857-00349 CPU3863
								857-00350
							
								CPU3863
								857-00350 CPU3864
								857-00351
							
								CPU3864
								857-00351 CPU3865
								857-00352
							
								CPU3865
								857-00352 ENIR-AXX-12SE
								857-00822
							
								ENIR-AXX-12SE
								857-00822 ENIR-BCT-12SE
								857-00824
							
								ENIR-BCT-12SE
								857-00824 ENIR-MBU-CB
								857-01071
							
								ENIR-MBU-CB
								857-01071 
							 
							 
 
					 
 
					 
 
					 
 
					 
 
					